Configure and launch an instance
After you configure your network settings on AWS, configure and launch the instances where you will install Vertica. An Elastic Compute Cloud (EC2) instance without a Vertica AMI is similar to a traditional host. Just like with an on-premises cluster, you must prepare and configure your cluster and network at the hardware level before you can install Vertica.
When you create an EC2 instance on AWS using a Vertica AMI, the instance includes the Vertica software and the recommended configuration. Vertica recommends that you use the Vertica AMI unmodified. The Vertica AMI acts as a template, requiring fewer configuration steps:
- 
Optionally, configure EBS volumes as a RAID array. 
- 
Launch instances and verify they are running. 
OpenText provides Vertica and Management Console AMIs on the Red Hat Enterprise Linux 8 operating system.
You can use the AMI to deploy MC hosts or cluster hosts. For more information, see the AWS Marketplace.
Configure EC2 instances in AWS
- 
Select a Vertica AMI from the AWS marketplace.For instance type recommendations for Eon Mode databases, see Choosing AWS Eon Mode Instance Types. 
- 
Select the desired fulfillment method. 
- 
Configure the following: 
- 
Number of instances to launch. A Vertica cluster usually uses identically configured instances of the same type. 
- 
VPC placement group 
 
Add storage to instances
Consider the following issues when you add storage to your instances:
- 
Add a number of drives equal to the number of physical cores in your instance—for example, for a c3.8xlarge instance, 16 drives; for an r3.4xlarge, 8 drives. 
- 
Do not store your information on the root volume. 
- 
Amazon EBS provides durable, block-level storage volumes that you can attach to running instances. For guidance on selecting and configuring an Amazon EBS volume type, see Amazon EBS Volume Types. 
Configure EBS volumes as a RAID array
You can configure your EBS volumes into a RAID 0 array to improve disk performance. Before doing so, use the vioperf utility to determine whether the performance of the EBS volumes is fast enough without using them in a RAID array. Pass vioperf the path to a mount point for an EBS volume. In this example, an EBS volume is mounted on a directory named /vertica/data:
[dbadmin@ip-10-11-12-13 ~]$ /opt/vertica/bin/vioperf /vertica/data
The minimum required I/O is 20 MB/s read and write per physical processor core on
each node, in full duplex i.e. reading and writing at this rate simultaneously,
concurrently on all nodes of the cluster. The recommended I/O is 40 MB/s per
physical core on each node. For example, the I/O rate for a server node with 2
hyper-threaded six-core CPUs is 240 MB/s required minimum, 480 MB/s recommended.
Using direct io (buffer size=1048576, alignment=512) for directory "/vertica/data"
test      | directory     | counter name        | counter | counter   | counter       | counter       | thread | %CPU  | %IO Wait  | elapsed | remaining
          |               |                     | value   | value (10 | value/core    | value/core    | count  |       |           | time (s)| time (s)
          |               |                     |         | sec avg)  |               | (10 sec avg)  |        |       |           |         |
--------------------------------------------------------------------------------------------------------------------------------------------------------
Write     | /vertica/data | MB/s                | 259     | 259       | 32.375        | 32.375        | 8      | 4     | 11        | 10      | 65
Write     | /vertica/data | MB/s                | 248     | 232       | 31            | 29            | 8      | 4     | 11        | 20      | 55
Write     | /vertica/data | MB/s                | 240     | 234       | 30            | 29.25         | 8      | 4     | 11        | 30      | 45
Write     | /vertica/data | MB/s                | 240     | 233       | 30            | 29.125        | 8      | 4     | 13        | 40      | 35
Write     | /vertica/data | MB/s                | 240     | 233       | 30            | 29.125        | 8      | 4     | 13        | 50      | 25
Write     | /vertica/data | MB/s                | 240     | 232       | 30            | 29            | 8      | 4     | 12        | 60      | 15
Write     | /vertica/data | MB/s                | 240     | 238       | 30            | 29.75         | 8      | 4     | 12        | 70      | 5
Write     | /vertica/data | MB/s                | 240     | 235       | 30            | 29.375        | 8      | 4     | 12        | 75      | 0
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 237+237 | 237+237   | 29.625+29.625 | 29.625+29.625 | 8      | 4     | 22        | 10      | 65
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 235+235 | 234+234   | 29.375+29.375 | 29.25+29.25   | 8      | 4     | 20        | 20      | 55
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 234+234 | 235+235   | 29.25+29.25   | 29.375+29.375 | 8      | 4     | 20        | 30      | 45
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 233+233 | 234+234   | 29.125+29.125 | 29.25+29.25   | 8      | 4     | 18        | 40      | 35
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 233+233 | 234+234   | 29.125+29.125 | 29.25+29.25   | 8      | 4     | 20        | 50      | 25
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 234+234 | 235+235   | 29.25+29.25   | 29.375+29.375 | 8      | 3     | 19        | 60      | 15
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 233+233 | 236+236   | 29.125+29.125 | 29.5+29.5     | 8      | 4     | 21        | 70      | 5
ReWrite   | /vertica/data | (MB-read+MB-write)/s| 232+232 | 236+236   | 29+29         | 29.5+29.5     | 8      | 4     | 21        | 75      | 0
Read      | /vertica/data | MB/s                | 248     | 248       | 31            | 31            | 8      | 4     | 12        | 10      | 65
Read      | /vertica/data | MB/s                | 241     | 236       | 30.125        | 29.5          | 8      | 4     | 15        | 20      | 55
Read      | /vertica/data | MB/s                | 240     | 232       | 30            | 29            | 8      | 4     | 10        | 30      | 45
Read      | /vertica/data | MB/s                | 240     | 232       | 30            | 29            | 8      | 4     | 12        | 40      | 35
Read      | /vertica/data | MB/s                | 240     | 234       | 30            | 29.25         | 8      | 4     | 12        | 50      | 25
Read      | /vertica/data | MB/s                | 238     | 235       | 29.75         | 29.375        | 8      | 4     | 15        | 60      | 15
Read      | /vertica/data | MB/s                | 238     | 232       | 29.75         | 29            | 8      | 4     | 13        | 70      | 5
Read      | /vertica/data | MB/s                | 238     | 238       | 29.75         | 29.75         | 8      | 3     | 9         | 75      | 0
SkipRead  | /vertica/data | seeks/s             | 22909   | 22909     | 2863.62       | 2863.62       | 8      | 0     | 6         | 10      | 65
SkipRead  | /vertica/data | seeks/s             | 21989   | 21068     | 2748.62       | 2633.5        | 8      | 0     | 6         | 20      | 55
SkipRead  | /vertica/data | seeks/s             | 21639   | 20936     | 2704.88       | 2617          | 8      | 0     | 7         | 30      | 45
SkipRead  | /vertica/data | seeks/s             | 21478   | 20999     | 2684.75       | 2624.88       | 8      | 0     | 6         | 40      | 35
SkipRead  | /vertica/data | seeks/s             | 21381   | 20995     | 2672.62       | 2624.38       | 8      | 0     | 5         | 50      | 25
SkipRead  | /vertica/data | seeks/s             | 21310   | 20953     | 2663.75       | 2619.12       | 8      | 0     | 5         | 60      | 15
SkipRead  | /vertica/data | seeks/s             | 21280   | 21103     | 2660          | 2637.88       | 8      | 0     | 8         | 70      | 5
SkipRead  | /vertica/data | seeks/s             | 21272   | 21142     | 2659          | 2642.75       | 8      | 0     | 6         | 75      | 0
If the EBS volume read and write performance (the entries with Read and Write in column 1 of the output) is greater than 20MB/s per physical processor core (columns 6 and 7), you do not need to configure the EBS volumes as a RAID array to meet the minimum requirements to run Vertica. You may still consider configuring your EBS volumes as a RAID array if the performance is less than the optimal 40MB/s per physical core (as is the case in this example).
Note
If your EC2 instance has hyper-threading enabled, vioperf may incorrectly count the number of cores in your system. The 20MB/s throughput per core requirement only applies to physical cores, rather than virtual cores. If your EC2 instance has hyper-threading enabled, divide the counter value (column 4 in the output) by the number of physical cores. See CPU Cores and Threads Per CPU Core Per Instance Type section in the AWS documentation topic Optimizing CPU Options for a list of physical cores in each instance type.If you determine you need to configure your EBS volumes as a RAID 0 array, see the AWS documentation topic RAID Configuration on Linux the steps you need to take.
Security group and access
- 
Choose between your previously configured security group or the default security group. 
- 
Configure S3 access for your nodes by creating and assigning an IAM role to your EC2 instance. See AWS authentication for more information.