CREATE SEQUENCE
Defines a named sequence number generator object. Named sequences let you set the default values of primary key columns. Sequences guarantee uniqueness, and avoid constraint enforcement issues.
For more information about sequence types and usage, see Sequences.
Syntax
CREATE SEQUENCE [ IF NOT EXISTS ] [[database.]schema.]sequence
[ INCREMENT [ BY ] integer ]
[ MINVALUE integer | NO MINVALUE ]
[ MAXVALUE maxvalue | NO MAXVALUE ]
[ START [ WITH ] integer ]
[ CACHE integer | NO CACHE ]
[ CYCLE | NO CYCLE ]
Parameters
IF NOT EXISTS
If an object with the same name exists, do not create it and proceed. If you omit this option and the object exists, Vertica generates a ROLLBACK error message. In both cases, the object is not created if it already exists.
The
IF NOT EXISTS
clause is useful for SQL scripts where you want to create an object if it does not already exist.For related information, see ON_ERROR_STOP.
[
database
.]
schema
Database and schema. The default schema is
public
. If you specify a database, it must be the current database.sequence
- Name of the sequence to create, where
sequence
conforms to conventions described in Identifiers. It must also be unique among all names of sequences, tables, projections, views, and models within the same schema. INCREMENT
Positive or negative integer that specifies how much to increment or decrement the sequence on each call to NEXTVAL, by default set to 1.
Note
Setting this parameter tointeger
guarantees that column values always increment by at leastinteger
. However, column values can sometimes increment by more thaninteger
unless you also set theNO CACHE
parameter.MINVALUE|NO MINVALUE
- Minimum integer value of the sequence. If omitted, the following defaults apply:
-
Ascending sequence: 1
-
Descending sequence: -263
-
MAXVALUE|NO MAXVALUE
- Maximum integer value of the sequence. If omitted, the following defaults apply:
-
Ascending sequence: 263
-
Descending sequence: -1
-
START
- Integer start value of the sequence. The next call to NEXTVAL returns the start value. If omitted, the following defaults apply:
-
Ascending sequence:
MINVALUE
-
Descending sequence:
MAXVALUE
-
-
CACHE|NO CACHE
Whether to cache unique sequence numbers on each node for faster access.
CACHE
takes an integer argument as follows:-
>1 specifies how many unique sequence numbers are pre-allocated and stored in memory for faster access. Vertica sets up caching for each session, and distributes it across all nodes.
Caution
If sequence caching is set to a low number, nodes are liable to request a new set of cache values more frequently. While it supplies a new cache, Vertica must lock the catalog. Until Vertica releases the lock, other database activities such as table inserts are blocked, which can adversely affect overall performance. -
0 or 1 specifies to disable caching (equivalent to
NO CACHE
).
By default, the sequence cache is set to 250,000.
For details, see Distributing sequences.
-
-
CYCLE|NO CYCLE
- Whether the sequence wraps:
-
CYCLE
:-
Incrementing sequence: On reaching
MAXVALUE
, wraps toMINVALUE
. -
Decrementing sequence: On reaching
MINVALUE
, wraps toMAXVALUE
.
-
-
NO CYCLE
(default): Calls to NEXTVAL return an error after the sequence reaches its upper or lower limit.
-
Privileges
Non-superusers: CREATE privilege on the schema
Examples